⚡ PX-180 failure? 4-hour response on plant-down enquiries — WhatsApp now
Energy Recovery PX-180 — 65 Series pressure exchanger

ERI PX-180 units and parts.
The 100–180 gpm 65 Series pressure exchanger, still in service.

The PX-180 is one of Energy Recovery’s earlier 65 Series pressure exchangers, and many are still running in small and mid-size SWRO plants. Meliora sources complete PX-180 units and 65 Series spare parts from Energy Recovery, confirmed against the serial number of the installed device.

100–180
gpm rated flow range
96.7%
Minimum guaranteed efficiency
4 hr
Plant-down response
48 hr
Standard quotations
PX-180 RFQ
Send the nameplate part number
and serial number.

Free to enquire. No obligation until you confirm your quote.

✓ RFQ received. Plant-down enquiries are answered within 4 hours, standard quotations within 48 hours.

or contact directly
WhatsApp — fastest for plant-down
← meliora.business

The PX-180: specifications, identification and replacement

In short: The Energy Recovery PX-180 is a legacy 65 Series pressure exchanger rated for 100 to 180 gpm (22.7 to 40.8 m³/h) with a minimum guaranteed efficiency of 96.7%. Complete units and spare parts are still supplied by Energy Recovery. Meliora sources them against the part number and serial number on the device nameplate.

Specifications

ItemPX-180
Series65 Series, with the PX-220 and PX-260
Flow range22.7–40.8 m³/h (100–180 gpm)
Minimum guaranteed efficiency96.7% at 36.3 m³/h
Moving partsOne, the ceramic rotor
Internal materialAluminium oxide ceramic
Wetted metal partsTitanium, super duplex and super austenitic stainless steel
HousingFibre-reinforced plastic
Electrical power requiredNone
ERI part number, complete unit40009-01

Source: Energy Recovery product catalogue. The part number is as shown on Energy Recovery nameplates and quotations for the PX-180.

The 65 Series family

The PX-180 shares its design with two larger devices. All three use the same principle: a ceramic rotor spins inside a ceramic sleeve between two end covers, and transfers pressure from the reject brine directly to incoming seawater.

ModelFlow rangeMinimum guaranteed efficiency
PX-18022.7–40.8 m³/h (100–180 gpm)96.7%
PX-22031.7–49.9 m³/h (140–220 gpm)96.8%
PX-26040.8–59 m³/h (180–260 gpm)96.8%

Parts for the two larger models are covered on the PX-220 and PX-260 page.

Is it a PX-180 or a PX-220?

This is the most common problem with these devices. The three 65 Series models look alike from the outside, and Energy Recovery’s older data sheets cover more than one model on the same page, so a plant holding the data sheet often cannot tell which device it has. Ordering the wrong one is an expensive mistake, because the flow ranges differ.

The nameplate settles it. Each device carries an Energy Recovery part number and a serial number. Send a photo of the nameplate and we ask Energy Recovery to confirm the model against that serial number before anything is quoted.

Units and parts we source

Energy Recovery states that PX devices contain no wear parts and need no routine maintenance. In practice, parts are ordered after an event: debris reaching the rotor, operation outside the flow limits, damage during handling, or seals disturbed when a device is opened. If a device is running but performing badly, the cause is often in the operating conditions and not in the device. See the PX troubleshooting guide before ordering parts.

Replacing a PX-180

There are two routes when a PX-180 has to be replaced.

Like for like. A new PX-180 fits the existing rack, pipework and control settings. Energy Recovery builds these units to order, so the lead time is the manufacturer’s production time plus freight. We state the current lead time on the quotation.

A current model. Energy Recovery’s present range is the PX Q Series, which includes the PX Q180. Whether a Q Series device can go into a rack built for 65 Series devices is an engineering question about connections, dimensions and flows. We put that question to Energy Recovery with your serial number and plant data, and pass on their answer.

If the plant has several devices in parallel, say how many are installed and how many have failed. A rack can sometimes keep running at reduced flow on the remaining devices while a replacement is built, but only within the flow limits of each device.

What to send us

PX-180 out of service? Send the nameplate photo. Plant-down enquiries get a reply within 4 hours, standard quotations within 48 hours.

Page reviewed October 2026 · Meliora FZCO, Dubai Silicon Oasis, UAE

Frequently Asked Questions

What is the flow range of the Energy Recovery PX-180?

The PX-180 is rated for 22.7 to 40.8 cubic metres per hour, which is 100 to 180 US gallons per minute. Energy Recovery gives a minimum guaranteed efficiency of 96.7% at 36.3 cubic metres per hour.

Is the PX-180 still available?

Yes. The PX-180 is a legacy 65 Series device, but Energy Recovery still supplies complete units and spare parts for it. Units are built to order, so the lead time is confirmed on each quotation.

What is the Energy Recovery part number for a PX-180?

Energy Recovery identifies the complete PX-180 pressure exchanger as part number 40009-01. The part number and serial number are on the device nameplate.

How do I tell a PX-180 from a PX-220 or PX-260?

From the nameplate. The three 65 Series models look similar and share older data sheets, so the part number and serial number on the nameplate are the reliable reference. Energy Recovery can confirm the model from the serial number.

Can a PX Q180 replace a PX-180?

The PX Q180 is the current Q Series device in the same flow class. Whether it can replace a PX-180 in an existing rack depends on connections, dimensions and operating flows, so it should be confirmed by Energy Recovery against the installed serial number.